VMware Cloud Director API - GET-VirtualHardwareSection-vApp
GET /vApp/{id}/virtualHardwareSection
- Operation:
- GET /vApp/{id}/virtualHardwareSection
- Description:
-
Retrieve the virtual hardware section of a VM.
This operation retrieves the entire VirtualHardwareSection of a VM. You can also retrieve many RASD item elements of a VirtualHardwareSection individually, or as groups of related items.
- Since:
- 0.9
- Input parameters
-
- Consume media type(s):
- None
- Input type:
- None
- Output parameters
-
ovf:VirtualHardwareSection_Type
- Produce media type(s):
-
application/vnd.vmware.vcloud.virtualHardwareSection+xml
application/vnd.vmware.vcloud.virtualHardwareSection+json
- Output type:
- VirtualHardwareSection_Type
- Examples
-
- Request
-
HTTP 1.1
GET /api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/
Headers:
x-vcloud-authorization: uJ13vBx80VGzZ0KcClBqxHNDJr3QI0K5KaQ0YKn2YZ0=
Body:
- Response
-
HTTP/1.1 200 OK
Headers:
Content-Length: 8266
Content-Type: application/vnd.vmware.vcloud.virtualhardwaresection+xml;version=5.5
Vary: Accept-Encoding
Body:
<?xml version="1.0" encoding="UTF-8"?><ovf:VirtualHardwareSection
xmlns:ovf="http://schemas.dmtf.org/ovf/envelope/1"
xmlns:rasd="http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2/CIM_ResourceAllocationSettingData"
xmlns:vcloud="http://www.vmware.com/vcloud/v1.5"
xmlns:vmw="http://www.vmware.com/schema/ovf"
xmlns:vssd="http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2/CIM_VirtualSystemSettingData"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
ovf:transport=""
vcloud:href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/"
vcloud:type="application/vnd.vmware.vcloud.virtualHardwareSection+xml"
xsi:schemaLocation="http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2/CIM_VirtualSystemSettingData http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2.22.0/CIM_VirtualSystemSettingData.xsd http://www.vmware.com/schema/ovf http://www.vmware.com/schema/ovf http://schemas.dmtf.org/ovf/envelope/1 http://schemas.dmtf.org/ovf/envelope/1/dsp8023_1.1.0.xsd http://www.vmware.com/vcloud/v1.5 http://https://vcloud.example.com/api/v1.5/schema/master.xsd http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2/CIM_ResourceAllocationSettingData http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2.22.0/CIM_ResourceAllocationSettingData.xsd">
<ovf:Info>Virtual hardware requirements</ovf:Info>
<ovf:System>
<vssd:ElementName>Virtual Hardware Family</vssd:ElementName>
<vssd:InstanceID>0</vssd:InstanceID>
<vssd:VirtualSystemIdentifier>importedVapp</vssd:VirtualSystemIdentifier>
<vssd:VirtualSystemType>vmx-08</vssd:VirtualSystemType>
</ovf:System>
<ovf:Item>
<rasd:Address>00:50:56:8d:7f:21</rasd:Address>
<rasd:AddressOnParent>0</rasd:AddressOnParent>
<rasd:AutomaticAllocation>false</rasd:AutomaticAllocation>
<rasd:Connection
vcloud:ipAddressingMode="DHCP"
vcloud:primaryNetworkConnection="true">VM Network</rasd:Connection>
<rasd:Description>E1000 ethernet adapter on "VM Network"</rasd:Description>
<rasd:ElementName>Network adapter 0</rasd:ElementName>
<rasd:InstanceID>1</rasd:InstanceID>
<rasd:ResourceSubType>E1000</rasd:ResourceSubType>
<rasd:ResourceType>10</rasd:ResourceType>
</ovf:Item>
<ovf:Item>
<rasd:Address>0</rasd:Address>
<rasd:Description>SCSI Controller</rasd:Description>
<rasd:ElementName>SCSI Controller 0</rasd:ElementName>
<rasd:InstanceID>2</rasd:InstanceID>
<rasd:ResourceSubType>lsilogicsas</rasd:ResourceSubType>
<rasd:ResourceType>6</rasd:ResourceType>
</ovf:Item>
<ovf:Item>
<rasd:AddressOnParent>0</rasd:AddressOnParent>
<rasd:Description>Hard disk</rasd:Description>
<rasd:ElementName>Hard disk 1</rasd:ElementName>
<rasd:HostResource
vcloud:busSubType="lsilogicsas"
vcloud:busType="6"
vcloud:capacity="40"/>
<rasd:InstanceID>2000</rasd:InstanceID>
<rasd:Parent>2</rasd:Parent>
<rasd:ResourceType>17</rasd:ResourceType>
</ovf:Item>
<ovf:Item>
<rasd:Address>0</rasd:Address>
<rasd:Description>IDE Controller</rasd:Description>
<rasd:ElementName>IDE Controller 0</rasd:ElementName>
<rasd:InstanceID>3</rasd:InstanceID>
<rasd:ResourceType>5</rasd:ResourceType>
</ovf:Item>
<ovf:Item>
<rasd:AddressOnParent>1</rasd:AddressOnParent>
<rasd:AutomaticAllocation>false</rasd:AutomaticAllocation>
<rasd:Description>CD/DVD Drive</rasd:Description>
<rasd:ElementName>CD/DVD Drive 1</rasd:ElementName>
<rasd:HostResource/>
<rasd:InstanceID>3002</rasd:InstanceID>
<rasd:Parent>3</rasd:Parent>
<rasd:ResourceType>15</rasd:ResourceType>
</ovf:Item>
<ovf:Item>
<rasd:AddressOnParent>0</rasd:AddressOnParent>
<rasd:AutomaticAllocation>false</rasd:AutomaticAllocation>
<rasd:Description>Floppy Drive</rasd:Description>
<rasd:ElementName>Floppy Drive 1</rasd:ElementName>
<rasd:HostResource/>
<rasd:InstanceID>8000</rasd:InstanceID>
<rasd:ResourceType>14</rasd:ResourceType>
</ovf:Item>
<ovf:Item
vcloud:href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/cpu"
vcloud:type="application/vnd.vmware.vcloud.rasdItem+xml">
<rasd:AllocationUnits>hertz * 10^6</rasd:AllocationUnits>
<rasd:Description>Number of Virtual CPUs</rasd:Description>
<rasd:ElementName>1 virtual CPU(s)</rasd:ElementName>
<rasd:InstanceID>4</rasd:InstanceID>
<rasd:Reservation>0</rasd:Reservation>
<rasd:ResourceType>3</rasd:ResourceType>
<rasd:VirtualQuantity>1</rasd:VirtualQuantity>
<rasd:Weight>0</rasd:Weight>
<vmw:CoresPerSocket
ovf:required="false">1</vmw:CoresPerSocket>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/cpu"
rel="edit"
type="application/vnd.vmware.vcloud.rasdItem+xml"/>
</ovf:Item>
<ovf:Item
vcloud:href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/memory"
vcloud:type="application/vnd.vmware.vcloud.rasdItem+xml">
<rasd:AllocationUnits>byte * 2^20</rasd:AllocationUnits>
<rasd:Description>Memory Size</rasd:Description>
<rasd:ElementName>4096 MB of memory</rasd:ElementName>
<rasd:InstanceID>5</rasd:InstanceID>
<rasd:Reservation>0</rasd:Reservation>
<rasd:ResourceType>4</rasd:ResourceType>
<rasd:VirtualQuantity>4096</rasd:VirtualQuantity>
<rasd:Weight>0</rasd:Weight>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/memory"
rel="edit"
type="application/vnd.vmware.vcloud.rasdItem+xml"/>
</ovf:Item>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/"
rel="edit"
type="application/vnd.vmware.vcloud.virtualHardwareSection+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/cpu"
rel="down"
type="application/vnd.vmware.vcloud.rasdItem+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/cpu"
rel="edit"
type="application/vnd.vmware.vcloud.rasdItem+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/memory"
rel="down"
type="application/vnd.vmware.vcloud.rasdItem+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/memory"
rel="edit"
type="application/vnd.vmware.vcloud.rasdItem+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/disks"
rel="down"
type="application/vnd.vmware.vcloud.rasdItemsList+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/disks"
rel="edit"
type="application/vnd.vmware.vcloud.rasdItemsList+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/media"
rel="down"
type="application/vnd.vmware.vcloud.rasdItemsList+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/networkCards"
rel="down"
type="application/vnd.vmware.vcloud.rasdItemsList+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/networkCards"
rel="edit"
type="application/vnd.vmware.vcloud.rasdItemsList+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/serialPorts"
rel="down"
type="application/vnd.vmware.vcloud.rasdItemsList+xml"/>
<vcloud:Link
href="https://vcloud.example.com/api/vApp/vm-89c84bd6-c6f2-4e4c-8a7d-c44a3489e2e4/virtualHardwareSection/serialPorts"
rel="edit"
type="application/vnd.vmware.vcloud.rasdItemsList+xml"/>
</ovf:VirtualHardwareSection>