VappPlannedMigrationSettings

VappPlannedMigrationSettings
VappPlannedMigrationSettings

Settings used when performing planned migration on a vApp level.

AllOf
JSON Example
{
    "copySecurityTags": true,
    "placementPolicy": "55a69531-ee2d-4cef-8df2-c68339e9e5ad",
    "powerOn": true,
    "sizingPolicy": "6d688c22-7736-44d3-8fcd-99d637eaef97",
    "vAppNetworkSettings": {
        "networkMappings": [
            {
                "sourceNetworkName": "ext_net_vdc_s1Org",
                "sourceOrgVdcNetwork": {
                    "id": "e5a39b99-6c27-493c-acce-7eae3cd7414e",
                    "name": "ext_net_vdc_s1Org"
                },
                "destinationOrgVdcNetwork": {
                    "id": "f1c31b8d-c36b-4c2e-9236-cf97f5046072",
                    "name": "ext_net_vdc_s2Org"
                }
            }
        ],
        "copySourceNetworks": true,
        "bridgeOrgVdcNetworks": [],
        "bulkConnectVmNics": false
    },
    "consolidate": false,
    "type": "string",
    "vmNetworkSettings": {
        "de68576d-7505-490e-ab9e-1942c2c965c4": {
            "primaryNicIndex": 0,
            "nics": [
                {
                    "nicIndex": 0,
                    "isConnected": true,
                    "resetMacAddress": false,
                    "network": "ext_net_vdc_s1Org",
                    "ipAddress": "",
                    "ipAddressAllocationMode": "POOL",
                    "externalIpAddress": "10.71.232.255",
                    "networkAdapterType": "",
                    "needsCustomization": false,
                    "macAddress": "00:50:56:8a:b2:a8"
                }
            ],
            "copySourceNicSettings": true,
            "computerName": "testpc",
            "enableGuestCustomization": true
        }
    },
    "storageProfileId": "8f5c7c85-dc5a-4e36-bf01-376df43af4b0"
}
boolean
consolidate
Optional

Indicates whether PITs should be consolidated or nothing should happen in the recovered VM. Defaults to false.

string
storageProfileId
Optional

When set, the given storage profile will be applied after the VM has been registered in VMware Cloud Director. Requirements are: vMotion, all ESXi hosts with access to the datastores which comprise the storage profile that was used to configure the replication need to have access to the datastores which comprise the new storage profile, all ESXi hosts with access to the datastores which comprise the new storage profile need to have access to the datastores which comprise the storage profile that was used to configure the replication.

string
type
Optional

Polymorphic discriminator property, value is 'vcloud'

object
vmNetworkSettings
Optional

Network settings for each VM organized as map by VM ID