NSX-T Data Center REST API
ParallelRedundancyProtocolConfig (type)
{
"description": "Provides all the necessary PRP config for vSwitch-RT enabled host switch. This config cannot be updated once host switch is created.",
"id": "ParallelRedundancyProtocolConfig",
"module_id": "TransportNode",
"nsx_feature": "EnsxDpVswitchRT",
"properties": {
"entry_forget_time": {
"default": 400,
"description": "How long (in ms) a packet with RCT to be held for duplication detection.",
"maximum": 600,
"minimum": 100,
"required": false,
"title": "Entry forget time",
"type": "int"
},
"life_check_interval": {
"default": 2000,
"description": "How often (in ms) supervision frame will be generated for the vPLC.",
"maximum": 4000,
"minimum": 2000,
"required": false,
"title": "Life check interval",
"type": "int"
},
"node_forget_time": {
"default": 60,
"description": "How long (in seconds) to wait for an idle Node to be deleted.",
"maximum": 120,
"minimum": 10,
"required": false,
"title": "Node forget time",
"type": "int"
},
"node_reboot_interval": {
"default": 500,
"description": "How long (in ms) for a reboot vPLC to be quiet before it can generate traffic.",
"maximum": 1000,
"minimum": 500,
"required": false,
"title": "Node reboot interval",
"type": "int"
},
"supervision_multicast_address": {
"$ref": "MACAddress",
"default": "01:15:4e:00:01:00",
"description": "Default multicast address for PRP supervision purpose.",
"required": false,
"title": "MAC Address"
}
},
"title": "Advanced PRP settings for vSwitch-RT enabled host switch",
"type": "object"
}