vSAN Management API


Data Object - VsanAutoRAIDInfo(vim.vsan.AutoRAIDInfo)

Returned by
VsanGetClusterRAIDInfo
Extends
DynamicData
Since
9.1.0.0

Data Object Description

Failure tolerance is determined together with hostFailuresToTolerate and subFailuresToTolerate. For standard cluster, subFailuresToTolerate is unset. Failure tolerance is determined by hostFailuresToTolerate.
hostFaiuresToTolerate subFailuresToTolerate Failure tolerance
0 unset 0
1 unset 1
2 unset 2
For stretched cluster, subFailuresToTolerate determines failure tolerance in site. hostFailuresToTolerate determines mirroring or not between sites.
hostFaiuresToTolerate subFailuresToTolerate Site mirroring Failure tolerance in site
0 0 No 0
0 1 No 1
0 2 No 2
1 0 Yes 0
1 1 Yes 1
1 2 Yes 2

Properties

Name Type Description
hostFailuresToToleratexsd:long

hostFailuresToTolerate value
subFailuresToTolerate*xsd:long

subFailuresToTolerate value
Properties inherited from DynamicData
None
*Need not be set
Show WSDL type definition