AlarmSetting

AlarmSetting
AlarmSetting

Tolerance and frequency limits of an alarm.

AllOf
This class requires all of the following:
JSON Example
{
    "_typeName": "string",
    "toleranceRange": 0,
    "reportingFrequency": 0
}
integer As int32 As int32
toleranceRange
Required

Tolerance range for the metric triggers, measured in one hundredth percentage.

A zero value means that the alarm triggers whenever the metric value is above or below the specified value. A nonzero value means that the alarm triggers only after reaching a certain percentage above or below the nominal trigger value.

integer As int32 As int32
reportingFrequency
Required

How often the alarm is triggered, measured in seconds.

A zero value means that the alarm is allowed to trigger as often as possible. A nonzero value means that any subsequent triggers are suppressed for a period of seconds following a reported trigger.