NSX-T Data Center REST API
Set VDS configuration and create it in vCenter (Deprecated)
Deprecated: NVDS-to-CVDS Upgrade Readiness Tool feature won't be supportedRequest:
Method:
              PUT
            URI Path(s):
              
                /policy/api/v1/infra/nvds-urt/topology-by-cluster/{precheck-id}?action=apply
                
              
            Request Headers:
                n/a
            Query Parameters:
    SetTargetVdsTopologyParameters+
  Request Body:
    UpgradeTopology+
  Example Request:
PUT https://<nsx-mgr>/policy/api/v1/infra/nvds-urt/topology-by-cluster/6a584dd7-9688-4a43-a27b-72f657e1fb80?action=apply { "topology": [ { "nvds_id": "bb 23 24 9d e4 0a 4c 62-91 9b 77 66 55 29 4c 92", "nvds_name": "mynvds1", "compute_manager_topology": [ { "compute_manager_id": "ddb8efeb-581e-435a-93b7-f95da399d7e0", "dvswitch": [ { "data_center_id": "domain-c8:70dade9c-eaf2-462b-9005-7ecf14595c19", "vds_name": "recommended-vds-name-cluster1", "transport_node_id": ["674007b3-5671-4409-911f-1c191ef492f7"], "cluster_id": "3e0f3566-8ebf-41b7-821e-3bd70ce81fa4:domain-c8" } ] } ] } ] }Successful Response:
Response Code:
                200 OK
              Response Headers:
                  
                  Content-type: application/json
                Response Body:
    UpgradeTopology+